Online water quality monitor
Beijing JXHS Environmental Protection Science Co., Ltd.

HS-810 Turbidity Monitor

HS-810 Turbidity Monitor 2019-6-30 This article has been read459 times

PS-HS-810型浊度监测仪.png

HS-810 Turbidity Monitor


Application field


Turbidity monitoring of pre-filtration, post-filtration, sedimentation and factory water in waterworks; water quality monitoring of municipal sewage;

The main technical parameters


1, measurement principle: using 90 ° scattered light


2. Range: 0.000~1.888NTU, 0.000~100.000NTU, 0.00~1000.00NTU, 0.0~10000.0NTU


3. Resolution: 0.001 NTU, 0.001 NTU, 0.01 NTU, 0.1 NTU


4. Precision: <±2%F.S <±5%F.S


5, repeatability: no more than 1%


6. Stability: Drift <0.1NTU/h


7, response time: <10sec


8, sampling period: 10sec


9, water sample conditions Flow: 10 ~ 40L / h Temperature: 10 ~ 45 ° C Pressure: 10 ~ 100KPa Impurity: solid matter is less than 5 microns, and no glue appears


10, the ambient temperature: 0 ~ 60 ° C


11, environmental humidity: <70% RH


12, analog output: galvanic isolation 0 ~ 10mA output (load <1.5 kΩ), 4 ~ 20 mA output (load <750Ω)


13, communication interface: RS485 or 232 (optional)


14, protection level: IP65


15, data preservation: 15 years


16, power: AC220V ± 22V, 50Hz ± 1Hz


17, power: 25W


18. Dimensions: 200×200×70mm (H×W×D)


19, opening size: 152 × 76mm (H × W)


Flow-through sensor size: 400 × 320 × 100mm (H × W × D)


Input sensor size: 260 × 185 × 95mm (H × W × D)


20, weight: 12kg


Selection guide


1. Optional flow-through and input-type sensors.


2, the installation method can be installed in disc type or wall-mounted.


Copyright©Beijing JXHS Environmental Protection Science Co., Ltd.